Cytofuge®12 Cytocentrifuge System Operator’s Manual A Division of IRIS International, Inc.

Page 2 - 12 Cytocentrifuge System

5 Error Indicators Cytofuge® 12 Cytocentrifuge error conditions are signaled by flashing codes appearing in the TIME display on the front panel.

Page 3 - Table of Contents

6 Section 3 Sample Requirements/Preparation Overview The approximate cell concentration of the specimen should be established prior to slide prepa

Page 4 - How to use this manual

7 Section 4 Operating Instructions Opening and Closing the Cover An electronic operated cover interlock mechanism prevents operation if the cover

Page 5

8 Spinning Samples CAUTION – Maintain a 300 mm (11.8 inches) clearance envelope around cytocentrifuge during operation. Do not deposit any potentia

Page 6 - Unpacking and Installation

9 Cytofuge 12 operating parameters generally depend upon the size and specific gravity of the cells to be concentrated onto the microscope slide. Th

Page 7 - Connect Power

10 Section 5 Maintenance Overview Iris Sample Processing recommends that instrument operators perform periodic inspections and preventative maintenan

Page 8 - System Overview

11 Checking/Replacing Rotor Seal Over time seals may become brittle and develop cracks. To ensure optimal rotor performance, check the inner and ou

Page 9 - CONTROL PANEL

12 Checking the Rotor Speed Rotor speeds (+5%) may be checked with a stroboscope or photoelectric tachometer. 1. Remove the rotor and locate the

Page 10 - Accessories

13 Service Refer all service to Iris Sample Processing or an Authorized Repair Facility. Instrument fuse(s) are located on the rear panel. Remove

Page 11 - Section 3

14 Section 6 Appendix Specifications Product Name Cytofuge® 12 Cytocentrifuge Product No. CF12 Model No. M802 Capacity 12 Filter and/or Cell concent

Page 12 - Operating Instructions

Operator’s Manual Cytofuge®12 Cytocentrifuge System Model Number M802 For in-vitro diagnostic use Product Number CF12 – Cytofuge 12 for 100-240

Page 13 - Loading

15 References 1. CLSI. “Protection of Laboratory Workers from Occupationally Acquired Infections; Approved Guideline-Third Edition.” CLSI documen

Page 14 - Unloading

16 Iris Sample Processing Warranty Iris Sample Processing, a Division of IRIS International, Inc. warrants that the cytocentrifuge shall be free fr

Page 15 - Maintenance

i Table of Contents How to use this manual ... ii Section 1 ...

Page 16 - 23-003019-137

ii How to use this manual This manual along with information contained on product labels and in package inserts should provide you with all the inf

Page 17

iii CAUTION – Do not lean, or place materials, on the cytocentrifuge. CAUTION - Follow Universal Precautions with all biological specimens, regardle

Page 18 - Service

1 Section 1 Unpacking and Installation Inspect Packaging The Cytofuge® 12 Cytocentrifuge and its accessories are delivered in a single carton. If t

Page 19 - Appendix

2 Connect Power o Plug the cytocentrifuge into a grounded outlet supplying 100-240 V @ 50-60 Hz. o Turn on the power switch (located on the rear

Page 20

3 Section 2 System Overview Principle and Intended Use For in vitro diagnostic use in concentrating cells onto a microscope slide. The Cytofuge® 12

Page 21 - Limitation of Liability

4 Operator Controls Start Initiates the selected cycle Stop/Open Interrupts the cycle and releases the cover when the rotor has stopped. Canc